Microwave-assisted tissue processing, fixation and staining in tissues of different thicknesses: A comparative study


1 Department of Oral Pathology and Microbiology, RVS Dental College and Hospital, Coimbatore, Tamil Nadu, India
2 Department of Oral Pathology and Microbiology, KVG Dental College and Hospital, Sullia, Karnataka, India
3 Department of Preventive Dental Science, College of Dentistry, King Saud Bin Abdulaziz University for Health Sciences, Riyadh, Saudi Arabia
4 Department of Maxillofacial Surgery and Diagnostic Science, College of Dentistry, King Saud Bin Abdulaziz University for Health Sciences, Riyadh, Saudi Arabia
5 Department of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia

Date of Submission08-Oct-2019
Date of Decision18-Dec-2019
Date of Acceptance21-Dec-2019
Date of Web Publication08-May-2020

Correspondence Address:
Mahesh Rao
Department of Oral Pathology and Microbiology, RVS Dental College and Hospital, Coimbatore, Tamil Nadu 641 402
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jomfp.JOMFP_290_19

Rights and Permissions

 

   Abstract 


Aim and Objectives: The study aimed at assessment of microwave assisted tissue fixation, processing and staining and to determine if it can replace standard formalin fixed paraffin embedded processing in tissues of different thickness.
Materials and Methods: Specimens from buccal mucosa and gingiva was used in the study and were divided into three different thickness and was fixed, processed and stained according to conventional method and with a use of kitchen microwave oven respectively. The present study is the first of its kind where oral tissues was fixed, processed and stained with a kitchen microwave in three different thickness. The results obtained was statistically analyzed using IBM SPSS Statistics version 21.0 software.
Results: The new technique of fixation, tissue processing and staining using a microwave employed in the present study represented a major change from conventional method and achieved significant reduction in time taken.
Conclusion: The ease of application and speed of this technique significantly reduced turnaround time in diagnostic labs.


Keywords: Fixation, kitchen microwave, processing, staining, thickness


How to cite this article:
Rao M, Pai SM, Khanagar SB, Siddeeqh S, Devang DD, Naik S. Microwave-assisted tissue processing, fixation and staining in tissues of different thicknesses: A comparative study. J Oral Maxillofac Pathol 2020;24:186

How to cite this URL:
Rao M, Pai SM, Khanagar SB, Siddeeqh S, Devang DD, Naik S. Microwave-assisted tissue processing, fixation and staining in tissues of different thicknesses: A comparative study. J Oral Maxillofac Pathol [serial online] 2020 [cited 2020 Aug 13];24:186. Available from: http://www.jomfp.in/text.asp?2020/24/1/186/283976





   Introduction Top


Routine use of formalin fixation, overnight dehydration, paraffin infiltration, manual embedding and sectioning has served well in producing relatively uniform, good quality tissue sections, but it is the major bottleneck in the workflow of histopathology laboratories. As we moved into the 21st century, the standard practice is now increasingly challenged because of its inability to meet the support required by current clinical demands. Because the routine manual histoprocessing remains laborious, time-consuming and requires toxic chemicals, alternative methods such as microwave tissue processing are the “future ray of hope.”[1]

The microwave-assisted tissue processing is believed to have brought a revolutionary improvement in histopathology. The technique shortens the tissue processing time from hours to minutes. The technique is responsive to the patient and physician needs, improves the use of reagents while reducing or eliminating their toxicity, creates a personnel-friendly workflow and places the laboratory in a better position to meet the demands of the rapidly expanding field of molecular medicine.[2] Thus, in brief, microwave tissue processing achieves three aims of reducing cost of reagents, reducing time taken and eliminating noxious materials from the process.[3]

Microwave technology has advanced to the point where a patient can come to a hospital or clinic in the morning, see a physician for a checkup, get a biopsy from a surgeon and, if the biopsy is sent to the laboratory by noon, have the results by 3 PM that afternoon. Improvements in equipment design and a better understanding of tissue processing using microwave technology make the catchphrase “same-day turnaround” a reality. This quick turnaround not only reduces patient anxiety and reagent use but also increases efficiency.[4] It was Boon et al. from The Netherlands and Antony Leong from Australia who advocated microwave heating for fixation and processing of tissues in the late 1980s.[2] The microwave used for histotechniques works on the principle that electromagnetic field causes excitation of molecules which brings about its rotation. This produces energy in the form of heat from within the materials. This heat enhances the rate of diffusion of fluids in and out of the tissue blocks or sections even more effectively in contrast to conventional heating.[5],[6],[7]

The pattern of microwave heat distribution depends on many physical parameters, which may include the electromagnetic field, the specific absorption rate and structure of the processed material and the geometrical dimensions of the processing cavity. One of the major drawbacks of microwave heating in food industry is the existence of hot spots in several zones depending on product geometry.[8] While a number of authors have reviewed the techniques and results of microwave-facilitated tissue fixation and processing, we are unaware of any previous studies comparing the quality of microwave processing and routine processing from matched specimens of different tissue thicknesses procured from the workload of an ordinary surgical pathology laboratory, using a commercially available microwave oven.

The purpose of the present study was to document the usefulness of kitchen microwave-assisted tissue fixation and processing and to determine whether it can replace standard formalin fixation and paraffin-embedded overnight processing as the new routine technique in tissues of different thicknesses.


   Materials and Methods Top


Specimens for the study were obtained from biopsies received from the Department of Periodontology (periodontal and gingival specimens following surgeries) and also from the Department of Oral Surgery (excision specimens from en bloc resection of carcinoma cases) of KVG Dental College and Hospital, Sullia, over a span of 1½ years. Biopsies from buccal mucosa and gingiva were included.

Method of collection of data

The study group comprised 15 buccal mucosal biopsies and 15 gingival biopsies of 10 mm × 10 mm dimensions. Each group was divided into two. One group was labeled as an experimental group and another as a control group. The experimental (microwave fixation and processing) and control groups (conventional fixation and processing) were divided into three subgroups, as shown in [Figure 1].
Figure 1: Distribution of study group

Click here to view


Materials used for the study comprised the following, as shown in [Table 1] and [Table 2].
Table 1: Microwave fixation and processing

Click here to view
Table 2: Conventional fixation and processing

Click here to view


Methodology

Five gingival surgery tissue specimens were processed as per microwave fixation and processing protocol to standardize the microwave fixation and processing in kitchen microwave used for the present study.

Each of the biopsy specimens was cut into approximately two equal halves, of which one bit was processed by conventional fixation and processing and another bit was processed by microwave fixation and processing. The tissues were processed by conventional method as per schedule mentioned in [Table 3].
Table 3: Conventional tissue fixation and processing method [Figure 2]

Click here to view


The tissue to be processed in microwave oven was wrapped in paper and placed in plastic cassettes and placed in bowl containing 100 ml of isopropyl alcohol. The bowl was then placed on the rotating table in microwave oven. The tissues were processed in microwave as per the schedule mentioned in [Table 4].
Table 4: Microwave tissue fixation and processing method

Click here to view


Microwave was operated at the lowest output power level of 100 W. Both the conventionally processed and microwave-processed tissues following impregnation in paraffin wax were embedded in paraffin wax using “L” blocks. The wax-filled mold containing the tissue was then allowed to cool. The hardened wax block was removed from the mold. Using semiautomatic soft-tissue microtome [Figure 2], the blocks were first trimmed and then sectioned at 5 μm thickness. Further, all the blocks were serially sectioned to consume the entire thickness of tissue. Sections obtained from routine and microwave-processed tissues were then mounted and then stained using hematoxylin and eosin (H & E) stain, as mentioned in [Table 5] and [Table 6] for conventional processing and microwave processing, respectively. Due to serial sectioning, a total of 150 paired slides processed by routine and microwave processing were obtained.
Figure 2: Semi-automatic soft tissue microtome

Click here to view
Table 5: Schedule for H & E staining by conventional method

Click here to view
Table 6: Schedule for hematoxylin and eosin staining by microwave method

Click here to view


The mounted slides were assigned a number and coded for routine and for microwave-processed tissues. These coded paired slides were then evaluated by three observers for the following criteria:

  1. Cellular clarity
  2. Nuclear details
  3. Cytoplasmic details
  4. Color intensity
  5. Epithelium and connective tissue interface.


These criteria were graded as follows:

  • Excellent = 3
  • Good = 2
  • Average = 1
  • Poor = 0.


Data analysis

The results so obtained from three observers were statistically analyzed using IBM SPSS Statistics Version 21.0. for (Windows, Armonk, NY: IBM Corp) using the following nonparametric tests:

  1. Wilcoxon's matched-pairs test
  2. Mann–Whitney test.



   Results Top


In this study, 150 pairs of slides of which one was routinely fixed processed and the others were microwave fixed and processed were stained simultaneously with H & E. The results obtained are tabulated in [Table 7], [Table 8], [Table 9], respectively.
Table 7: Microwave processing versus conventional processing of tissues <4 mm

Click here to view
Table 8: Microwave processing versus conventional processing of tissues <5-8 mm

Click here to view
Table 9: Microwave processing versus conventional processing of tissues >9 mm

Click here to view


Color intensity and epithelium and connective tissue interface were statistically significant in tissues of <4 mm thickness, as shown in [Table 7] and [Figure 3]. Color intensity was statistically significant in tissues of 5 –8 mm thickness, as shown in [Table 8] and [Figure 4].
Figure 3: (a) Microwave processing versus conventional processing of tissues <4 mm. (b) Microwave processing versus conventional processing of tissues <4 mm

Click here to view
{Table 8}
Figure 4: (a) Microwave processing versus conventional processing of tissues <5 mm–8 mm. (b) Microwave processing versus conventional processing of tissues <5 mm–8 mm

Click here to view


Cellular clarity, color intensity and epithelium and connective tissue interface were statistically significant in tissues of >9 mm thickness, as shown in [Table 9] and [Figure 5].{Table 9}
Figure 5: (a) Microwave processing versus conventional processing of tissues >9 mm. (b) Microwave processing versus conventional processing of tissues >9 mm

Click here to view


Cellular clarity and epithelium and connective tissue interface were statistically significant, as shown in [Table 10].
Table 10: Microwave tissue processing versus conventional tissue processing

Click here to view


A comparison of turnaround time of microwave tissue fixation, processing and staining with conventional tissue fixation, processing and staining is shown in [Table 11].
Table 11: Turnaround time of microwave versus conventional processing and staining

Click here to view



   Discussion Top


The new technique of fixation and tissue processing using a microwave employed in the present study represents a major change from conventional fixation and tissue processing. The ease of application and speed of this technique has significantly reduced turnaround time in diagnostic laboratories for the past three decades. Initially, application of microwave techniques into histotechnology was not accepted but nowadays is growing in its popularity and versatility.

Serial sectioning was done in the present study, consuming the entire tissue to ensure the analysis of histomorphologic features throughout the tissue thickness. The two different protocols of tissue processing showed a similar kind of results considering the various histologic parameters in tissues of different thicknesses with the microwave-processed tissues of <4 mm and 5–8 mm showing better color intensity. Interface of epithelium and connective tissue has been a special area of interest for a pathologist in ruling out invasion and in many other immune-mediated disorders.[9] When the integrity of epithelial tissues was considered, the present study revealed better results in microwave-processed tissues of <4 mm thickness. However, the cellular clarity, color intensity and epithelium and connective tissue interface were better in tissues of >9 mm thickness processed in conventional method. This may be attributed to the formation of “hot spots” in microwave oven in case of tissues with greater thickness. Inhomogeneous energy dissipation means selective heating of different parts of the material is possible and may lead to temperature gradients in the microwave oven. The presence of these zones with a higher temperature than others is termed as hot spots.[8] As a result, uniform heat distribution is not possible. In the present study, this factor might have led to nonuniform processing in tissues of greater thickness.

While considering all the tissues in total, irrespective of the tissue thickness, there were no significant differences when considering nuclear details, cytoplasmic details and color intensity; however, cellular clarity and epithelium and connective tissue interface were superior in tissues processed in conventional method than microwave processing. This may be attributed to the incorporation of tissues >9 mm thickness in the evaluation. In a study done by Babu et al., cellular clarity, cytoplasmic details, nuclear details and color intensity were slightly better in microwave method than in routine method.[10] Similar studies by various authors showed no significant differences in the histologic quality when they compared these two protocols.[9],[11],[12],[13]

From the perspective of the end product, microwave irradiation substantially shortens the time from specimen reception to diagnosis. In the present study, the slides were ready in 113 min with microwave tissue fixation and processing as compared to 515 min in addition to the overnight fixation in routine processing and staining. This allowed same-day tissue processing and diagnosis of small biopsy specimens without compromising the overall quality of histologic sections. This is in agreement with Rohr et al.[3] where histological slides were produced in 2–3 h using microwave irradiation. In a study done by Babu et al.,[10] the turn around time for microwave tissue fixation and processing and staining was 75 min. In a study done by Henwood A,[14] the tat for microwave tissue fixation and processing was 80 min. Relatively longer duration for microwave tissue processing in the present study can be attributed to the low power option chosen to ensure minimum tissue damage and prevent boiling of chemicals. In a study done by Patil S et al.,[15] microwave processing was found suitable, and drastic reduction in tat was noted which led to early reporting of slides.

The kitchen microwave oven used in the present study had a maximum output of 800 W, but it was operated at the lowest output of 100 W throughout the study. Although literature from various studies suggest that the microwave can be operated at higher output levels, i.e., 200–2000 W, in turn, reducing the time of processing from 1 to 2 h to as less as 5 min,[3] the lowest output of 100 W was preferred since evaporation and boiling of chemicals were noted when microwave was operated at higher power.

Metals and metallic utensils are contraindicated for use in microwave oven due to total internal reflection of microwaves, leading to sparkling,[5] hence plastic cassettes in place of metal cassettes during tissue processing were used. These cassettes are relatively cheap and can be reused.

Those working in the laboratory pursue a reduction or preferably elimination of toxic reagents from histopathology. Microwave procedures are conducive to that aim because the volume of reagents used and the toxic exposure are significantly lower. In particular, replacing xylene with mineral oil or isopropyl alcohol for clearing and excluding formaldehyde for fixation from processing through microwave methods is a welcome improvement in histopathology. Ethyl alcohol is a good dehydrating agent, and isopropyl alcohol dehydrates and has been found to be a good intermedium or clearing agent. The current study supports the same and has demonstrated comparable results, implying that microwave fixation with alcohol provides a good and faster fixation which is comparable to routine fixation. Isopropanol is less toxic than xylene and is cheaper than both chloroform and xylene. Isopropanol is not very popular as a clearing agent in conventional histoprocessing because of its slow diffusion. In microwave technique, the problem of slow diffusion can be overcome by microwave heating. Even Kok and Boon in their study found that during microwave impregnation, xylene could not be boiled out because of its high boiling point and low microwaveability and thus retarded the diffusion of paraffin, whereas highly microwavable isopropanol could be easily boiled out. Like others, paraffin wax for impregnation has been used in the present study as well.[11]

In spite of several advantages over conventional histoprocessing methods, the present study revealed a few limitations of microwave tissue processing. In kitchen microwave oven used for the histoprocessing, the temperature and exact power control were not standardized and vacuum processing was not available. Although the histologic quality of tissues >9 mm was inadequate, the present study achieved reduction in time taken, eliminating noxious reagents and comparable microscopic features in tissues of <4 mm and 5–8 mm. The present study is the first of its kind where oral tissues were fixed processed and stained with a kitchen microwave in three different thicknesses.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Morales AR, Essenfeld H, Essenfeld E, Duboue MC, Vincek V, Nadji M. Continuous-specimen-flow, high-throughput, 1-hour tissue processing. A system for rapid diagnostic tissue preparation. Arch Pathol Lab Med 2002;126:583-90.  Back to cited text no. 1
    
2.
Boon ME, Kok LP, Ouwerkerk-Noordam E. Microwave-stimulated diffusion for fast processing of tissue: Reduced dehydrating, clearing, and impregnating times. Histopathology 1986;10:303-9.  Back to cited text no. 2
    
3.
Rohr LR, Layfield LJ, Wallin D, Hardy D. A comparison of routine and rapid microwave tissue processing in a surgical pathology laboratory. Quality of histologic sections and advantages of microwave processing. Am J Clin Pathol 2001;115:703-8.  Back to cited text no. 3
    
4.
Slap SE. New developments in microwave histoprocessing. Am Biotechnol Lab 2003;11:40-4.  Back to cited text no. 4
    
5.
Microwaves Processing Technique for Microscopy. Available from: http:/www.ebsciences.com/papers/microwaves.htm#stimulator. [Last accessed on 2015 Apr 13].  Back to cited text no. 5
    
6.
Sivadas P, Kumar H, Lakshmanan C, Bhardwaj JR. Microwave stimulated fixation and rapid processing of tissue for histopathology. Med J Armed Forces India 1996;52:157-60.  Back to cited text no. 6
    
7.
Kok LP, Boon ME. Microwaves for microscopy. J Microsc 1990;158:291-322.  Back to cited text no. 7
    
8.
Hotz A. Ortiz AD, Moreno A. Microwaves in organic synthesis: Thermal and non-thermal microwave effects. Chem Soc Rev 2005;34:164-78.  Back to cited text no. 8
    
9.
Shashidara R, Sridhara SU. Kitchen microwave-assisted accelerated method for fixation and processing of oral mucosal biopsies: A pilot study. World J Dent 2011;2:17-21.  Back to cited text no. 9
    
10.
Babu TM, Malathi N, Magesh KT. A comparative study on microwave and routine tissue processing. Indian J Dent Res 2011;22:50-5.  Back to cited text no. 10
[PUBMED]  [Full text]  
11.
Naik SN, Patel S, Astekar M, Rao D. Comparison of clarity of nucleocytoplasmic differentiation of oral tissues processed by microwave and conventional methods. Ann Diagn Pathol 2012;16:128-33.  Back to cited text no. 11
    
12.
Panja P, Sriram G, Saraswathi TR, Sivapathasundharam B. Comparison of three different methods of tissue processing. J Oral Maxillofac Pathol 2007;11:15-7.  Back to cited text no. 12
  [Full text]  
13.
Katoh K. Microwave-assisted tissue preparation for rapid fixation, decalcification, antigen retrieval, cryosectioning, and immunostaining. Int J Cell Biol 2016;(9):1-9.  Back to cited text no. 13
    
14.
Henwood A. Improving placental block morphology using microwave-assisted fixation. J Histotechnol 2018;17:98-10.  Back to cited text no. 14
    
15.
Patil S, Rao RS, Nagaraja A, Kumar SD. Comparision of conventional and microwave histoprocessing of various soft tissues. J Dent Res Rev 2014;1:3-6.  Back to cited text no. 15
  [Full text]  


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4], [Table 5], [Table 6], [Table 7], [Table 8], [Table 9], [Table 10], [Table 11]



 

Top
Print this article  Email this article
            

    

 
   Search
 
  
    Similar in PUBMED
    Search Pubmed for
    Search in Google Scholar for
  Related articles
    Article in PDF (1,497 KB)
    Citation Manager
    Access Statistics
    Reader Comments
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed148    
    Printed3    
    Emailed0    
    PDF Downloaded31    
    Comments [Add]    

Recommend this journal

Journal of Oral and Maxillofacial Pathology | Published by Wolters Kluwer - Medknow
Online since 15th Aug, 2007